NET MONITOR
TEST 10

TMSIaaaaaaaa
T321:bbb/ccc
PRP:d ee ff
ggggg hhh

        aaaaaaaa    TMSI value in hex format

        bbb      Current value of T3212 counter (range is 000 - 'ccc', where
                    1 means 6 min time.  So, if this value is 2 less than 'ccc'
                    then next periodic location updating will be made within
                    2 * 6 min = 12 minutes.

        ccc       Timeout value of T3212 counter (range is 000 - 240, where 1
                    means 6 min time between location updates and 240 means
                    240 * 6 min = 24 h between location updates. 000 means that
                    periodic location update is not in use.)  This value is
                    received from the network.

        d          Value of paging repeat period (range is 2 - 9, when paging
                    is in every second multiframe, mobile takes more current
                    than if it were in every 9th multiframe)

        ee         Downlink signalling failure value. If value is negative,
                    0 is shown. Maximum value is 45. When mobile is on TCH
                    then xx is shown.

        ff          Gain value on TCH/SDCCH, range is 0 - 93

    ggggg      VCTCXO AFC DAC control, range is -1024 - 1023

        hhh      Serving cell channel number