SOTTOSISTEMA DELLO SPETTROMETRO COMPOSITO A INFRAROSSI (CIRS)

Il CIRS è progettato per misurare l'energia infrarossa di diverse lunghezze d'onda nel sistema saturniano.It will address a wide variety of science objectives for the atmospheres of Saturn and Titan, and for Saturn's icy satellites and rings, including composition determination and thermal state measurements. The CIRS instrument consists of two assemblies: optics and electronics. For information on these components, click on their names.
 
 

(CIRS Links)

The CIRS optics assembly consists of a telescope, a far infrared interferometer, a mid infrared interferometer, a reference interferometer, a moving scan mechanism, a cooler, thermal control equipment, an optics assembly mount, covers for the telescope and cooler, and a calibration shutter mechanism. For information on these components, click on their names.
 
 

(Optics Assembly Links)

The telescope is composed of a 50.8 cm-diameter paraboloid primary mirror and a hyperboloid secondary mirror. A sun  shade will be present around the primary mirror. This shade will also serve as the primary mirror radiator. A cylindrical tube extends from the central portion of the primary mirror to support the secondary mirror, which has its own radiator.

The CIRS science data will be collected by two of the instrument's three interferometers. Interferometers are instruments designed to make precise measurements of wavelength within some range of the electromagnetic spectrum. For example, the CIRS far infrared (FIR) interferometer covers a spectral range of 10-600 cm-1. The FIR instrument is a polarizing interferometer that uses substrate-mounted wire grid polarizers to polarize and analyze the radiation. The interferometer operates by first polarizing the radiation and then modulating its polarization. The FIR interferometer has its moving mirror mounted on one end of the moving scan mechanism, which it shares with the mid infrared interferometer. The fixed and moving mirrors are roof mirrors, and the FIR focal plane consists of a matched pair of thermopile detectors, each with a concentrator.

The mid-infrared (MIR) interferometer, which is a conventional Michelson instrument, covers a spectral range of 600-1500 cm-1. The MIR interferometer has its moving mirror mounted on the opposite end of the moving scan mechanism from the FIR mirror. The fixed and moving mirrors are cube corners, and the MIR uses a germanium lens to focus the interferometer output onto focal planes FP3 and FP4.

The reference interferometer will provide timing correlation of the science data sampling to the scan mechanism position.. Specifically, the scan mechanism's motion will produce a variable reference interferometer signal that will be used to generate the timing signals necessary to time the recording of science data. The reference interferometer is a Michelson instrument, used on-axis at the optic center of the MIR interferometer. It includes laser diode and LED sources, a quartz beamsplitter/compensator, optics, and a silicon detector. The reference interferometer uses cube corners for the fixed and moving mirrors.

The moving scan mechanism subassembly includes the optical and mechanical components in the optics assembly required for moving the interferometer mirrors to permit controlled sampling in the optical path difference. This subassembly consists of a common carriage with a moving shaft for the three interferometer mirrors, a motor to drive the shaft, a cantilever-spring motor mount, and a velocity transducer. The scan mechanism includes a launch lock that can be locked and unlocked repeatedly without refurbishment by remote command through the onboard computer.

A single-stage, passive cooler, radiating to space, provides a 70-80 K cold finger with four discrete, commandable set points within that range. The nominal set point temperature will be 80 K. The cold finger has heaters for decontamination and detector annealing.

A system of thermal control equipment, including temperature sensors, electrical heaters, proportional heater controllers, and radiators, is used to maintain the thermal control of the optics assembly. The temperature of the instrument is monitored by sensors located at appropriate places in the instrument, including, but not limited to, the telescope mirrors, the interferometers, the detectors, the optics housing, the radiating surface, and the Michelson motor.

The optics assembly mount thermally decouples the optics assembly from the remote sensing pallet (RSP).

The telescope and 80-K cooler will be protected with covers until the orbiter leaves the inner solar system, at which point the covers will be separately jettisoned by wax thermal actuators (WTAs). Each cover has two redundant parrafin actuators, either one of which can initiate the action of a pin-puller assembly, which in turn initiates the action of an ejection spring assembly.

The calibration shutter mechanism will be used to interrupt the MIR beam, causing the MIR detectors to view a controlled 170-K black surface inside the instrument. The shutter is commandable through the onboard computer.
 
 

The CIRS electronics assembly includes front-end electronics, scan mechanism electronics, reference interferometer electronics, temperature control and monitor electronics, the instrument data system, and power converter electronics for conditioning the spacecraft power as required by the instrument. For information on these components, click on their names.
 
 

(Electronics Assembly Links)

The front-end electronics provides analog and digital processing of the detector signals. This includes filtering, multiplexing, amplification, and digitization to achieve the science data requirements.

The scan mechanism electronics provides the operation and control of the linear moving scan mechanism. The control system provides a constant velocity travel during the forward (scan) direction and a fast flyback during the reverse (flyback) direction. The control is a function of the reference interferometer timing signals and other sensors, as needed. The scan mechanism electronics also includes circuitry to actuate the calibration shutter.

The reference interferometer electronics provides timing signals for accurate sampling of the science data and for accurate control of the scan mechanism velocity.

The CIRS instrument has four zones that are independently controlled by the temperature control and monitor electronics. These zones are the primary mirrors, the secondary mirrors, the interfermeters, and the 80-K cooler. The temperature is monitored by temperature sensors located on the four zones, which provide accurate temperature values at the cooled temperatures. The sensors located on the optics assembly provide course values at the decontamination temperature. The monitored temperatures will be transmitted to the spacecraft.

The instrument data system (IDS) is a microprocessor circuit that provides the instrument data processing function and communication with the spacecraft. The IDS receives and processes commands, data, and timing information from the spacecraft and configures and controls the instrument's operational states. It processes the science data from the front-end electronics and the housekeeping data from all of the subassemblies, and then it transmits these data to the spacecraft.

The power converter electronics (PCE) conditions the regulated power received from the spacecraft and provides direct power to the instrument data system and the temperature controller and monitor subassemblies. The PCE also provides, on command, power to other subassemblies and release of the scan mechanism launch lock, the 80-K cooler cover, and the telescope cover.
 
 